TM 55-1905-220-14-6
3-118.
TORQUE COUPLING - MAINTENANCE INSTRUCTIONS.(Continued)
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (Cont)
10.
Install seal ring (29).
cover
half
(8)
NOTE
For best results, assemble
standard couplings with
minimum misalignment and
with "normal gap". Heat
small interference fit
hubs in an oven or in oil.
The oil flash point rust
he 350-F (177 C) or higher.
Apply flare heat evenly to
large hubs.
3-2001


 