Custom Search
 
  
 
TM 55-1905-220-14-7
3-171.2. CONNECTING ROD - MAINTENANCE INSTRUCTIONS (Cont).
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY
10. Orifice
Orifice
Install from the upper
Install orifice
(7)
bearing area.
0.3125 inch
(0.7938 cm)
from lower
surface.
11. Spray
Spray
a. Insert nozzle straight
Align holes in
nozzle
nozzle
into the counterbore
spray nozzle as
(8),
of the connecting
shown.
and
rod.
connecting
rod
(3)
b. Support the connecting
rod in the arbor press.
Place a short 3/8 inch
I.D. sleeve on top of
the nozzle and press
the nozzle into the
connecting rod until
it bottoms in the
counterbore.
3-2908


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business