Custom Search
 
  
 
TM 55-1905-220-14-7
3-178. HYDROSTARTER PUMP (ENGINE - DRIVEN) - MAINTENANCE INSTRUCTIONS
(Continued)
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
6. Hand
Relief
Release the oil pressure
pump
valve
in the system by opening
relief valve on side of
the hand pump about 1/2
turn.
WARNING
The oil pressure in the system must be released prior to
servicing the pump or other parts to prevent possible injure to
personnel or equipment.
7.
Supply hose
a. Clean exterior dirt off.
b. Disconnect supply hose
(1) at swivel fitting (2)
c. Tape hose end to keep
Use masking
out dirt.
Tape
3-3020


 


Privacy Statement - Copyright Information. - Contact Us