4-5. GENERAL (Continued).
Table 4-17. Water Closet Gravity Timer Malfunction Troubleshooting.
NOTE
Refer to paragraph 4-15 for maintenance instructions.
MALFUNCTION -
TEST OR INSPECTION
CORRECTIVE ACTION . . .
1. Will not cock.
Step 1. No vacuum or low vacuum.
Disconnect line from top of timer and check for vacuum.
Step 2. Ruptured diaphragm.
Replace.
Step 3. Activation valve not assisting.
Troubleshoot activation valve assembly.
2. Will not honor low vacuum hold.
Step 1. Vacuum switch (N.O.) broken.
Replace.
Step 2. Vacuum switch (N.O.) out of position.
Adjust position of switch by loosening mounting screws.
3. Will not activate water dispensing valve or vacuum dispensing valve.
Step 1. Vacuum switch (N.C.) broken.
Replace.
Step 2. Vacuum switch (N.C.) is out of position.
Adjust position of switch by loosening mounting screws.