4-5. GENERAL (Continued).
Table 4-20. Sewage System Sewage Discharge Valve
Troubleshooting.
NOTE
Refer to paragraph 4-15 for maintenance instructions.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Discharge valve.
Step 1. No vacuum or low vacuum supply.
Check vacuum pressure gage at collection tank.
Step 2. Line loose or broken to bottom of valve.
Tighten or replace line.
Step 3. Blockage to outlet tube.
Clear line.
Step 4. Malfunction of gravity timer.
See Gravity Timer Troubleshooting guide.
Step 5. Ruptured diaphragm or fracture lower or upper body.
Replace valve.