Custom Search
 
  
 
TM 55-1905-220-14-8
4-7.5. MAGNETO ASSEMBLY - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Con')
t
7.
Condens-
a. Screw
Remove.
ers
(11) and
(typical)
lead
b. Screw
Remove.
(12), and
(13)
c.
Condens-
Install.
Make certain that
er (13),
all contact surfaces
and screw
are clean and free
(12)
of foreign matter
and that terminal
nuts or screws are
made secure to guard
against faulty igni-
tion. All electrical
connections must be
clean, free of corro
sign, and tight.
d. Screw
Install
(11), and
lead
8.
Breaker
a. Screw
Remove.
point
(11)
assembly
(typical)
b. Coil
Remove.
(14), and
leads
(13)
4-170


 