Custom Search
 
  
 
TM 55-1905-220-14-8
4-7.5A.
PRIMING PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR
7.
Fan belt
a. Screws (40)
Remove two places.
b. Fan belt
Remove.
guard (41)
c.
Fan belt
1. Check fan belt tension
(25)
by pushing fan belt in
at point shown below.
Verify that fan belt
deflection is 5/32
inch.
2. Adjust fan belt as
follows:
(a) Loosen the four
screws (42) on the
priming pump mount-
ing bracket (28),
and the two screws
(11) and (13) on
the priming pump
stabilizer bracket
(9).
(b) Slide the priming
pump (7) out to
tighten fan belt
(25).
(c) When fan belt
deflection is
5/32 inch:
Tighten four
screws (42) on
the priming
pump mounting
bracket (28),
and the two
screws (11) and
(13) on the
priming pump
stabilizer
bracket (9).
4-352


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business