Custom Search
 
  
 
TM 55-1905-220-14-8
4-13.1.
DIESEL OIL COOLING PUMP SER - MAINTENANCE INSTRUCTIONS.
This task covers:
a. Inspection
c. Disassembly
e. Installation
b. Removal
d. Reassembly
INITIAL SETUP
Test Equipment
References
NONE
NONE
Equipment
Special Tools
Condition Condition Description
NONE
NONE
Material/Parts
Special Environmental Conditions
Gaskets 209-4661560-J12
NONE
2 each
Personnel Required
General Safety Instructions
2
Observe WARNING.
LOCATION
ITEM
ACTION
REMARKS
To prevent accidental shock and possible injury, tag and place
disconnect switch in the OFF position.
INSPECTION
1.
Pump set
a. Piping
Inspect for breaks,
cracks, or leaks.
b. Wiring
Inspect for breaks,
cracks, fraying or
disconnections.
c
Housing
Inspect for cracks,
dents, or leaks.
d. Hardware
Insure all hardware
i
is tight.
4-575


 