Custom Search
 
  
 
TM 55-1905-220-14-8
4-16.2. WATER CLOSET TIMER - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
CAUTION
Do not activate cam or linkage, as the diaphragm in
the timer may be damaged.
REPAIR
3.
Vacuum
a. Screws (5),
Remove.
switches-
flatwashers
normally
(6), and
closed
mounting
spacers
(7)
b. Vacuum
Replace.
switch (8)
c.
Mounting
Install.
spacers (7),
flatwashers
(6), and
screws (5)
NOTE
Adjust switch mounting position for proper operation.