4-18.1. SEWAGE SYSTEM VACUUM PUMP - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
f.
Center stud
Remove.
(26), and
adapter
(27)
g.
All parts clean and blow dry.
h.
Adapter
Replace.
(27), and
center
stud (26)
i.
Lower cap
Replace.
(25), and
wick (24)
j.
Strainer
Replace.
felt (8)
and spring
(7)
k.
Gasket (6)
Replace.
and glass
cylinder
(5)
l.
Gasket (4)
Replace.
and cap (3)
m. Oil
Add oil.
Type OE/HDO 20.
n.
Gasket (2)
Replace and tighten.
and filler
plug (1)
4-674


 