TM 55-1905-220-14-8
4-19.2. SEWAGE DISCHARGE PUMP MOTOR - MAINTENANCE INSTRUCTIONS
(Continued).
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
3.
a. Wiring
Tag and disconnect.
b. Locknuts
Remove.
Remove shims if
(1), and
present in in-
screws
stallation.
(2)
c.
Motor
Slide out of coupling
(4) and remove.
d. Key (5)
Remove.
INSTALLATION
4.
a. Key (5)
Install on motor shaft.
b. Motor
Align with coupling (4)
(3)
and insert.
c.
Screws
Install and tighten.
Reinstall any
(2), and
shims.
nuts (1)
d. Wiring
Remove tags and
reconnect.