Custom Search
 
  
 
TM 55-1905-220-14-8
4-21.1. SEWAGE SYSTEM MOTOR CONTROLLER-MAINTENANCE INSTRUCTIONS
(Continued).
LOCATION
ITEM
ACTION
REMARKS
REPAIR (Cont)
7
.Lamp
a.
Lens (25)
Lift out.
If lamp is de-
assembly
fective.
(single)
(23), and
b.
Indicator
Rotate turn
If necessary.
Lamp as-
lamp (26)
counterclockwise to
sembly
remove.
(double)
(24)
c.
Holder(27)
Rotate turn
counterclockwise to
remove.
d.
Wiring
Tag and disconnect.
Refer to wiring
diagram FO-1.
e.
Retaining
Remove.
nut(28)
f.
Lamp assem-
Remove.
bly(29)
g.
Lamp assem-
Replace.
bly (29),
and retain-
ing nut
(28)
h.
Wiring
Reconnect. Remove
tags.
i.
Holder (27)
Rotate 1/2 turn clock-
wise to install.
8.
Reset
Retaining nut
Replace.
If necessary.
button
(30), button
(31), and
spacer (32)
9.
Trans-
a.
Wiring
Tag and disconnect.
Refer to wiring
former
diagramFO-1.
b.
Screws (33)
Remove.
c.
Replace.
(34)
4-736


 