4-22.1. VENT PIPING - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION
ITEM
ACTION
REMARKS
INSPECTION
1.
Vent
Flange
1. Inspect for breaks
For repairs,
piping
and cracks.
refer to Direct
Support Mainte-
nance.
2. Inspect for leaking
The smell of
gasket.
sewage will be
present.
3. Insure all hardware
is tight.
REPAIR
2.
a.
Nuts (1),
Remove.
and screws
(2)
b.
Gasket (3)
Separate flanges and
Discard gasket.
remove gasket.
Clean flanges
of gasket
material.
c.
Gasket (3)
Replace.
Use new gasket.
d.
Screws (2),
Reinstall in flanges.
and nuts
(1)