Custom Search
 
  
 
SECTION II
TM 55-1905-220-34P
(1)
(2)
(3)
(4)
(5)
(6)
ITEM  SMR
PART
NO  CODE CAGEC
NUMBER
DESCRIPTION AND USABLE ON CODES (UOC)
QTY
GROUP 09
PUMP SETS
FIG.
337
STARTER
XDCZZ 27192
A10BNLOX
STARTER 3 POLE 3 PHASE NON- ..........................
3
REVERSING AC MAGNETIC 965 SIZE 0 .................
1
XDCZZ
27192
25-2217
CONNECTOR OVERLOAD RELAY ..........................
1
2
PACZZ
27192
H1021
HEATER, THERMAL RELE................................ .......
1
3
PACZZ
27192
H1034
HEATER, THERMAL RELE................................ .......
1
4
XDCZZ
27192
10-3523-5
RELAY OVERLOAD................................ ..................
1
5
XDCZZ
27192
C10BX
POWER UNIT STARTER................................ ..........
1
6
PACZZ
27192
9-1887-17
COIL, ELECTRICAL ................................ ..................
1
END OF FIGURE