Figure 2-25. Bilge Overboard Discharge Valves.
NOTE
One additional bilge overboard discharge valve is located on the opposite side of the engine room.
(d) Open bilge pump suction valves (figs. 1-13 and 2-9) as needed to pump bilge compartments.
(e) Engage clutch on appropriate bilge pumps (fig. 2-9).
2-13.
FIRE EXTINGUISHERS.
a. General. There are four C02 fire extinguishers aboard the vessel. One is in the pilot house, one in the engine
compartment, and two in the cargo well.
b. Operating Squeeze Grip C02 Extinguisher.
(1) Carry the extinguisher in an upright position and approach the fire as closely as the heat permits.
(2) Remove the locking pin from the valve.
(3) Grasp the horn handle.
(4) Squeeze the release lever and at the same time direct the carbon dioxide flow toward the base of the fire.
2-59


 