Custom Search
 
  
 
TM 55-1905-221-14-1
Table 3-1. Troubleshooting (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2.
Check for loose connections or defective starting motor switch.
a. Tighten any loose connections. Report a defective switch to your supervisor.
b. If switch is not defective, go to Step 3.
Step 3.
Check lubricating oil used.
a. Use proper oil as specified in the lubrication order.
b. If proper oil is being used, go to Step 4.
Step 4.
Check for low fuel supply.
a. Refill fuel tank if empty or low.
b. If fuel is not low, go to Step 5.
Step 5.
Check for loose connection or cracked lines between fuel pump and tank. Report any
loose connections or cracked lines to your supervisor.
2. LACK OF POWER.
Check for low fuel supply.
Fill fuel tank.
3. HIGH LUBRICATING OIL CONSUMPTION.
Step 1.
Check for leaking oil lines or connections.
a. If oil lines are leaking, notify your supervisor.
b. If there is no loose connection or leaking oil lines, go to Step 2.
Step 2.
Check for gasket or oil seal leakage.
a. If gaskets or oil seals are leaking, notify your supervisor.
3-3


 


Privacy Statement - Copyright Information. - Contact Us