Custom Search
 
  
 
TM 55-1905-221-14-1
4-39.
ROCKER ARM.
This task covers:
a. Inspection
b. Adjustment
INITIAL SETUP
Equipment
Condition
Paragraph
Condition Description
Test Equipment
Rocker Cover Removed
NONE
Tools and Special Tools
Special Environmental Conditions
General Mechanic Tool Kit
NONE
Gage Set: Feeler
Material/Parts
General Safety Instructions
NONE
NONE
Personnel Required
Troubleshooting Reference
Operator-Crew
NONE
(MOS 61B & C)
References
Approximate Time Required (minutes)
NONE
Inspection
30
Location/Item
Action
Remarks
INSPECTION AND ADJUSTMENT
1. Rocker Arm
a. Loosen the push rod locknut.
b. Place a 0.013 inch feeler gage,
tool J9708, between the valve
stem and the rocker arm.
4-135


 