Custom Search
 
  
 
TM 55-1905-221-14-2
5-27.
RAW WATER PUMP (Continued)
LOCATION/ITEM
ACTION
REMARKS
REPAIR ON ENGINE (Cont)
WARNING
Dry cleaning solvent, P-D-680, used to clean parts, is potentially
dangerous to personnel and property. Avoid repeated or prolonged skin
contact. Do not use near open flame or excessive heat. Flash point of
solvent is 100138 (38-59C).
-
F
e. Clean all parts with cleaning
solvent P-D-680 and dry
thoroughly.
f.
Install seal assembly (5) on
Use new seal
pump drive shaft (6).
assembly.
g. Compress impeller blades enough
Use new
to clear offset cam (7) and
impeller.
press impeller (4) onto splined
end of drive shaft (6).
h. Position cover plate gasket (3)
Use new gasket.
in place on pump body.
i.
Install cover (2) onto body with
Use new screws.
screws (1).
5-503


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business