Custom Search
 
  
 
TM 55-1905-221-14-3
6-5.7
STEERING SYSTEM FLOW CONTROL VALVE (Continued).
LOCATION/ITEM
ACTION
REMARKS
DISASSEMBLY (Cont)
c.
Withdraw spool assembly
(6) and gasket (7).
d. Remove preformed packing
(8, 9, and 10).
CLEANING
2. Flow Control
Valve
Dry cleaning solvent, P-D-680, used to clean parts,
is potentially dangerous to personnel and property.
Avoid repeated or prolonged skin contact. Do not
use near open flame or excessive heat. Flash point
of solvent is 100138 (3859 ).
-
F
-
C
Clean metal parts in cleaning
solvent Fed. Spec. P-D-680 and
dry thoroughly.