Custom Search
 
  
 
TM 55-1905-221-14-3
6-10.
RAMP, RAMP CABLES, SHEAVES, LATCH MECHANISM AND SEAL
(Continued).
LOCATION/ITEM
ACTION
REMARKS
DISASSEMBLY (Cont)
6. Cable Sheaves
a. Remove sheave pin (1).
b. Remove flat thrust washers
(2) from sheave (3).
c.
Remove bushing halves (4)
Use arbor press
from sheave (3).
to remove.
CLEANING
7. Ramp, Ramp
Cables, and
Sheaves
Dry cleaning solvent, P-D-680, use to clean parts,
is potentially dangerous to personnel and property.
Avoid repeated or prolonged skin contact. Do not
use near open flame or excessive heat. Flash point
of solvent is 100- 138 (38 59 ).
F
-
C
Clean parts in cleaning solvent
Fed. Spec. P-D-680 and dry
thoroughly.
INSPECTION
8. Ramp, Ramp
a. Inspect wire rope for broken
Cables, and
strands, kinks or other
Sheaves
damage.
6-94


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business