Custom Search
 
  
 
TM 55-1905-221-14-3
6-19.
STARTING MOTORS (ELECTRIC) (Continued).
LOCATION/ITEM
ACTION
REMARKS
ASSEMBLY
9. Frame and
a. Place inside insulator
Field
washer (21), flatwasher
Assembly
(20) and insulation strip
(19) on field terminal
stud (17) and insert into
field frame (18).
b. In order, place insulated
bushing (16), stud
insulator (15), washer
(14), lockwasher (13),
stud nut (12), lockwasher
(11), and terminal stud
nut (10) on terminal
stud (17) and tighten
nuts.
c.
Install ventilators (9
and 8) in field frame
(18).
d. Position in place the
two pieces of field coil
insulation strips (7 and
6).
e. Position in field frame
two field coil assemblies
(5 and 4) and four pole
shoes (3).
f.
Secure with pole screws
(2).
g. Resolder field coil leads
(1) to terminal studs
(17).
6-222


 