TM 55-1905-221-14-3
6-27.4.
CYLINDER LINER - MAINTENANCE INSTRUCTIONS (Continued).
LOCATION/ITEM
ACTION
REMARKS
INSTALLATION (Cont)
Minimum
Maximum
Limit
.0000 (.0000 cm)
.0020 (.0051 cm)
.0025 (.0064 cm)
b. Install hold down clamp.
Use tool
J21793-01.
c.
Measure the distance from the
top of the liner to the top
of the block with a dial
indicator. The liner flange
must be .045 to .050 inch
(.1143 to .1270 cm) below
the surface of the block.
However, even though all of
the liners are within these
specifications, there must
not be over .002 inch (.0051
cm) difference in depth
between any two adjacent
liners when measured along
the cylinder longitudinal
center line.