6-31. FUEL INJECTORS (Continued).
LOCATION/ITEM
ACTION
REMARKS
TESTING (Cont)
NOTE
Before using the injector tester, or when refilling it with fuel oil, disconnect the
tube of the gage and operate the handle until all the air is expelled from the
system. Then connect the tube to the gage.
b. Valve opening (pop-pressure) test.
(1) Place the fuel injector in the
testing and popping fixture as
shown, with dowel on the under-
side of the injector located in
the proper slot of the adaptor
plate. Position injector
support plate and popping
handle support to the proper
height.