Custom Search
 
  
 
TM 55-1905-221-14-4
6-33. RAW WATER PUMP (Continued).
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1. Hose, Lines,
and Water Pump
NOTE
Drain raw water system.
a. Loosen hose clamps (1) on
outlet line hose (2).
b. Remove hose (2).
c. Remove pipe (3) from water
pump flange (5).
d. Remove nuts (4) and flange
(5) from water pump (10).
e. Remove nuts (6) from inlet
line (7).
f. Remove inlet line (7).
g. Remove adapter to flywheel
mounting bolts (8) and lock-
washers (9).
NOTE
Using a wood block or soft hammer, loosen pump from flywheel housing by tapping on edge of
adapter.
h. Withdraw pump (10) with
attached adapter straight
out from flywheel housing,
disengaging drive gear
from coupling.
i. Remove gasket.
Discard.
CAUTION
Cover pump opening in flywheel housing with a clean cloth to prevent entrance of foreign matter.