Custom Search
 
  
 
TM 55-1905-222-14
3-13 SERVICE STARTING SYSTEM RESERVOIR AND FILTERS (Continued).
2.
CLEAN FILTER
WARNING
Dry cleaning solvent, P-D-680, used to clean parts, is potentially dangerous
to personnel and property. Avoid repeated or prolonged skin contact. Do
not use near open flame or excessive heat. Flash point of solvent is 100-
138F (3859C).
-
Clean gasket (4), filter element (5), seat guide (6),
spring (7) and filter housing (2).
3.
INSPECT FILTER ELEMENT AND GASKET.
a.
Visually inspect filter element (5) and gasket (4) for
any defects.
b.
Get new filter element and gasket if necessary;
reuse If in good condition.
4.
ASSEMBLE AND INSTALL FILTER.
a.
Assemble spring (7), seat guide (6), filter element
(5) and gasket (4) in filter housing (2).
b.
Fill filter housing (2) with clean hydraulic fluid MIL-
H-5606 to displace air.
c.
Install filter assembly onto filter cap (3).
5.
SERVICE 40 MICRON IN-LINE FILTER.
Service the in-line filter (8) using the procedures
outlined above.  Refer to para 5-46 for removal
procedure.
3-43


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business