Custom Search
 
  
 
TM 55-1905-222-14
4-27 REPLACE FILTER, DISINFECTION UNIT AND RETENTION CANISTERS (Continued).
REMOVAL
REMOVE DISINFECTION UNIT
a. Remove tubing assembly (8) from tee (9)
Remove tubing assembly (10) from
disinfection unit outlet port.
b
Remove breather (11) from tee (9).
c
Remove two nuts (12) and lockwashers (13)
from U-bolt (14).
d. Remove disinfection unit (15) from mounting
base (7) and remove tee (9) from inlet port of
disinfection unit. Replace disinfection unit.
INSTALLATION
INSTALL DISINFECTION UNIT
a. Install tee (9) In inlet port of disinfection unit
(15).
b. Install disinfection unit (15) on mounting
base (7) and secure with U-bolt (14),
lockwashers (13) and nuts (12)
c. Install breather (11) and tubing assembly
(8) on tee (9).
d. Install tubing assembly (10) in disinfection
unit outlet port.
4-55


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business