Custom Search
 
  
 
TM 55-1905-222-14
MAINTENANCE OF HYDRAULIC STARTING SYSTEM
5-45 REPLACE ACCUMULATOR.
This task covers
a. Removal
b. Installation
INITIAL SETUP
Tools:
Equipment Conditions.
Tool Kit, Mechanic's, Rail
Engine shut down. All fluid pressure on
and Marine
hydraulic starting system released.
General Safety Instructions:
Ensure that the hydraulic pressure in
the system is relieved before working
on system.
REMOVAL
REMOVE ACCUMULATOR
a. Close valve on accumulators not
being replaced.
WARNING
The fluid pressure in the system must be released prior to servicing the accumulator to
prevent possible injury to personnel or damage to equipment.
b. Remove nuts (1), lockwashers (2), and bolts
(3) from mounting brackets (4).
c. Remove accumulator (5) from mounting
brackets. Unscrew accumulator from bottom
hydraulic connection (6).
5-116


 


Privacy Statement - Copyright Information. - Contact Us