Custom Search
 
  
 
TM 55-1905-222-14
5-46
REPLACE FILTERS (STARTING SYSTEM) (Continued).
INSTALLATION
INSTALL FILTER ASSEMBLY
a. Install male connector (6) into the inlet port of
the filter assembly.
b. With the outlet port oriented towards the control
valve, screw the filter assembly into the
reducing hex nipple (5).
c. Connect hose assembly (4) onto the male
connector (6) on the inlet side of the filter
assembly.
d. Secure filter housing (3) with U-bolt (I) and nut
(2).
REMOVAL
REMOVE AND DISASSEMBLE T-TYPE FILTER
a. Close starting system shutoff valve (12) in the
suction line from the tank.
b. Unscrew the filter housing (13) from the head
(14).
c. Remove and discard 'O' ring (8) and filter
element (9) Get new parts.
d. Remove seat guide (10) and spring (11) from
filter housing (13).
5-120


 


Privacy Statement - Copyright Information. - Contact Us