6-17 REPAIR RECHARGING PUMP (Continued).
i. Remove drive shaft (9), washer (40), needle
bearing (41) and washer (42)
j. Remove piston (43) and retaining rings (44)
k. Press oil seal (45) and roller bearing (46)
from mounting flange assembly (39) using an
arbor press Remove and discard 'O' ring (47)
NOTE
The carrier needle bearing (48) in housing (12) should only be removed if it is to be replaced.
Sleeve (49) has been shrink-fitted into the housing. It is not replaceable.
3. DISASSEMBLE DRIVE ASSEMBLY
a. Separate intermediate drive (50) from flange
assembly (51)
b. Remove oil seal (52) from flange assembly (51)
CLEANING
CLEAN PUMP PARTS.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts, is
potentially dangerous to personnel and property. Avoid
repeated or prolonged skin contact.  Do not use near open
flame or excessive heat. Flash point of solvent is 100- 138
F
(38 59 ).
-
C
a. Clean all parts thoroughly in
cleaning solvent, Fed Spec P-D-
680.