(4)  Galley duct heater DH-12A (20).Galley duct heater DH-12A is a duct mounted, flanged type,
electric heater which provides heating for the aft galley area.
(5)  Galley duct heater DH-12 (21).Galley duct heater DH-12 is a duct mounted, flanged type,
electric heater which provides heating for the forward galley area.
(6)  Engine room supply fan SF-1 (22).Engine room supply fan SF-1 is an axial fan with electric
motor direct drive which provides forced supply air for the engine room port side. The fan is enclosed in a
watertight enclosure on the lower main weather deck port side.
(7)  Mess room duct heater DH-11 (23). Mess room duct heater DH-11 is a duct mounted,
flanged type, electric heater which provides heating for the mess room.
(8)  Engine room supply fan SF-2 (24).Engine room supply fan SF-2 is an axial fan with electric
motor direct drive which provides forced supply air for the engine room starboard side. The fan is enclosed in a
watertight enclosure on the lower weather main deck starboard side.
(9)  Recreation room duct heater DH-16 (25). he recreation room duct heater DH-16 is a duct
T
mounted, flanged type, electric heater which provides heating for the recreation room.
(10) Deck/sick bay toilet convection heater CH-14 (26).The deck/sick bay toilet convection
heater CH-14 is a convection type electric space heater provides heating for the main deck/sick bay toilet.
(11) Sick bay duct heater DH-15 (27). he sick bay duct heater DH-15 is a duct mounted, flanged
T
type, electric heater which provides heating for the sick bay.
(12) Arms control room duct heater DH-14 (28). he arms control room duct heater DH-14 is a
T
duct mounted, flanged type, electric heater which provides heating for the arms control room.
(13) Emergency generator room supply fan SF-5 (29).he emergency generator room supply fan
T
SF-5 is a panel fan with electric motor direct drive provides forced supply air to the emergency generator room,
drawn in from a watertight, bolted-on inlet louver on the starboard bulkhead.
(14) Main accommodation air conditioning unit AC-1 (30)The accommodation air conditioning
.
unit AC-1 is a 16-ton capacity air conditioner assembly located in the emergency generator room. The unit
provides conditioned air to all accommodations rooms on the 01 level (FIGURE 1-32, Sheet 2) as well as those
rooms indicated on the main deck (FIGURE 1-32, Sheet 3).
(15) Emergency generator room unit heater UH-6 (31)Unit heater UH-6 is a forced air, electric
.
space heater which provides heating for the emergency generator room.