Custom Search
 
  
 
TM 55-1905-223-10
Table 2-1. Description of Operator's Controls and Indicators - CONT
Key
Control or Indicator
Function
Main Switchboard (FIGURE 2-28) - Continued
52
MISC. MCHRY
Protects power panel P204 from amperage overload.
POWER PANEL
P204
60AT
53
SPARE
Spare circuit breaker if additional distribution
30AT is required with 30 ampere circuit protection.
54
FIRE PUMP 2
Protects fire pump No. 2 from amperage overload.
P207
100AT
55
STERN ANCHOR WINCH
Protects stern anchor winch from amperage
P219
100AT
overload.
56
MCHRY SPACES
Protects power panel P211 with automatic trip
VENT PANEL
circuit breaker with under-voltage trip
P211
125AT/UVT
protection.
57
ENG. ROOM
Protects power panel P210 with automatic trip
VENT MCC
circuit breaker with under-voltage trip
P210
200AT/UTV
protection.
58
WELDER
Protects power panel P223(1) from amperage
P223(1
125AT
overload.
59
PORT
Protects port steering gear-with instantaneous
STEERING GEAR
magnetic trip circuit protector.
P224
30ATINS
60
FWD. HEATER
Protects power panel P201 from amperage overload.
POWER PANEL
P201
150AT
61
MCHRY SPACES HTR
Protects power panel P203 from amperage overload.
PWR PNL
P203
175AT
62
SPARE
Spare circuit breaker if additional distribution
80AT
is required with 80-ampere circuit protection.
63
F.W. PUMP 2
Protects fresh water pump No. 2 from amperage
P218
15AT
overload.
64
HOT WATER HTR
Protects hot water heater from amperage overload.
P216
35AT


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business