Custom Search
 
  
 
TM 55-1905-223-10
Table 2-2. Operator/Crew Preventive Maintenance Checks and Service - CONT
B - Before
D - During
A - After
W - Weekly
M - Monthly
INTERVAL
PROCEDURES
EQUIPMENT IS
ITEM
ITEM TO BE
CHECK FOR AND HAVE REPAIRED
NOT READY/
NO
B
DA W M
INSPECTED
OR ADJUSTED AS NECESSARY
AVAILABLE IF:
74
Bow Ramp
Hydraulic Power
Pack Assembly -
continued
c. Temperature
Check fluid temperature with
l
Level Sensor
hydraulic power pack operating.
Temperature should be at, or
below, 150 .
F
Bow Ramp Winch
Check for loose or broken
l
Assembly
brackets, leaking fittings, or
other unusual conditions.
a. Oil Level
Check for oil visible in sight
l
glass.
l b. Outboard Drum
Check for outboard drum bearing
bearing
lubrication. Refer to LO 55-
1905-223-12.
l c. Slack Wire
Check for slack wire limit
switch lubrication. Refer to
LO 55-1905-223-12.
l d. Interlock
Check for interlock switch
Switch
lubrication. Refer to LO 55-
1905-223-12.
NOTE
Refer dripping oil and hydrau-
lic fluid leaks to your super-
visor and unit maintenance.
75
Starboard Bow
Check hydraulic power pack for
l
Anchor Windless debris, foreign objects, and
Hydraulic Power loose or broken fittings.
Pack Assembly
2-249


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business