TM 55-1905-223-10
Power Generation.
a.
On Emergency Switchboard (FIGURE 2-87), set EMG SWBD 120V XFMRS (1), WHL/HSE EMG
LTG PNL (2), and EMERG LIGHT BELOW MN DECK (3) circuit breakers to ON position.
(1) On Wheelhouse Emergency Lighting Panel (EL102), set circuit breaker6 to ON position.
b.
On Main Switchboard (FIGURE 2-89), set WHEELHOUSE LIGHTING PANEL (1), ENG ROOM
LIGHTING PANEL (2) and MN DECK LIGHTING PANEL (3) circuit breakers to ON position.
(1) On Engine Room Lighting Panel L102, set circuit breakers 2, 3, 6, 7, 11 and 14 to ON position.
(2) On Wheelhouse Lighting Panel L105, set circuit breaker 2 to ON position.
(3) On Main Deck Lighting Panel L104, set circuit breakers 1, 2, 4, 5, 6, 13, and 16 to ON position.
c.
On Auxiliary Machinery Motor Control Center (FIGURE 2-90).
(1) Set STBD SSDG JACKET WATER HEATER NO. 1 circuit breaker (1) to ON position.
(2) Set PORT SSDG JACKET WATER HEATER NO. 2 circuit breaker (2) to ON position.
(3) Set STBD MAIN ENGINE JACKET WATER HEATER NO. 1 circuit breaker (3) to ON position.
(4) Set PORT MAIN ENGINE JACKET WATER HEATER NO. 2 circuit breaker (4) to ON position.
d.
Align Fuel Oil Filter, Transfer, and Supply Piping System (FIGURE 2-92; Sheet 1) to the starboard ship
service diesel generator (electric start) as follows:
(1) Close all valves in Fuel Oil Filter, Transfer, and Supply Piping System.
(2) Open FO-33, DAY TK F-12S SUPPLY TO STBD MN ENG & SSDG (17).
(3) Open FO-39, RETURN FR STBD SSDG TO DAY TK F-12S (15).
(4) Open FO-31, SUPPLY TO STBD SSDG (9).
e.
Align SSDG Fresh Water Cooling System (FIGURE 2-93) as follows:
(1) Close all valves in the Fresh Water Cooling System.
(2) Open FWC-15, EXP TK-SSDG STBD (7).


 