(b) On Auxiliary Machinery Motor Control Center (FIGURE 2-163) set L.O. PUIER circuit breaker
RIF
(1)
to the ON position.
(c) Set L.O. PURIFIER HEATER circuit breaker (2) to the ON position.
NOTE
8
L.O. Purifier Heater is used if engine oil temperature is below 1F.0
(d) On Lube Oil Heater Switch (FIGURE 2-164) release LOCK (3), press START pushbutton (1).
(e) Close all valves in the Lube Oil Purification and Transfer Piping System (FIGURE 2-165).
(f) If L.O. Purifier Heater is to be used, open LO-9, PRE-HEATER SUPPLY (27, FIGURE 2-165) and
LO-8, PRE-HEATER OUTLET (29).
(g) If L.O. Purifier Heater is NOT to be used, open LO-7, PRE-HEATER BY-PASS (30).
(h) If STBD Main Engine lube oil is to be purified:
1. Open LO-19, SUMP SUCT-STBD ENG (17).
2. Open LO-15,-PRE-LUBE/PURIFIER SUCT (23).
3. Open LO-25, SUMP SUPPLY/Purifier RTN - STBD ENG (15).
4. Ensure LO-17, RDCN GEAR SUCT-STBD (22) is closed.
(i)
if Port Main Engine lube oil is to be purifier:
1 Open LO-18, SUMP SUCT-PORT ENG (12).
2 Open LO-14, PRE-LUBE/PURIFIER SUCT (14).
3 Open LO-24,SUMP SUPPLY/PURIFIER RTN PORT ENG (6).
4. Ensure LO-16, RDCN GEAR SUCT-PORT (4) is closed.
(j)
Open ILO06, LO PURIFIER DISCH (31).
(2)
Start L.O. Purifier.
(a) On L.O. Purifier TYPE-I Motor Switch (FIGURE 2-166) release LOCK (3), press START pushbutton
(1).
(b) Wait 5 minutes for bowl inside purifier to gain speed.
(c) Open LO-6, LO PURIFIER DISCH (31, FIGURE 2-165).
(d) Slowly open LO-11, PURIFIER SUCTION (32, FIGURE 2-165) until oil is visible in sight glass on top
of purifier.