Custom Search
 
  
 
TM 55-1905-223-10
(d) Open SW-30, ENG EXHAUST CUTOUT (1) (located on main deck underneath the port
forecastle ladder).
(e) At the Bowthruster Engine Control Panel (FIGURE 2-263), set STARTER CUTOUT SWITCH
(4) in the up position. Set START SWITCH (3) in the up position.
(f) Press PUSH TO CRANK pushbutton (2).
CAUTION
If engine fails to start within 30 seconds, release PUSH TO CRANK (1) pushbutton.
Wait 2 minutes to allow starter motor to cool before using it again.
(g) Allow engine to idle for 3 'to 5-'minutes until ENGINE WATER (5) gauge starts to rise.
CAUTION
If ENGINE OIL gauge (6) does not rise to 45 psi within 15 seconds, stop engine or
equipment damage could result. Notify unit maintenance.
NOTE
All Diesel Engines, except Main Engines, on the LCU have an Automatic Low Oil
Pressure Shutdown System.  This system will activate at a low oil pressure
condition and shut engine down.
b. Emergency Fire Pump Operation.
(1) Open SEA CHEST VENT (7, FIGURE 2-262).
(2) Open SEA CHEST VENT ISOLATION (3).
(3) Open FM-19, EMER FIREPUMP SEA CHEST ISLN (30, FIGURE 2-264).
(4) Open FM-20, EMER FIREPUMP DISCH (31).
(5) CLOSE FM-15, NO, 2 FIRE PUMP DISCH (15).
(6) CLOSE FM-14, NO. 1 FIRE PUMP DISCH (16).
(7) CLOSE FM-13, FIREMAIN & BALLAST CROSS CONN (29).
(8) At Engine Room Console (FIGURE 2-265), set CONTROL AIR SELECTOR (1) to the engine room
position.
(9) Start Emergency Fire Pump by shifting clutch arm aft.
(10) Control engine speed with throttle linkage.
2-688


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business