a.
Condition: Operational test, check capacity, check for inspection tags on reservoirs and relief valves, check oil
pressure when warmed up.
Standard: Units are operational, capable of pumping 200 gal reservoir to 175 psi from empty in less than 12
minutes. Test tags indicate test at previous OCCM (313 psi for tanks, 220 psi for relief valves, oil pressure 18-
20 psi when warmed up. NOTE: OCCM specification will normally provide for hydrostatic test of reservoir and
setting of relief valves. ___________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
NOTE: On some craft air compressors are located in tunnel, same procedure applies.
b.
Sea Water Cooling Pump:
Condition: Verify operational condition inspect for leaks, normal pressure.
Standard: Unit operates and maintains pressure without excessive vibration or noise, no leaks from shaft seal
or piping or pipe joints and flanges. __________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
c.
Stbd Main Engine Including Reduction Gear, Propeller Shaft, and Bearings, Shaft Brake
and Controls:
Condition: Test operates at dock or underway. Inspect for leaks (lube oil, fuel oil, water, and exhaust gas).
Check temperatures and pressures for normal readings. Check engine response to control both reversing and
acceleration from all stations. Check for vibration, of all components. Check shaft brake operation. Review
log for unusual or abnormal operating conditions or incidents. Review oil analysis reports and oil consumption
records for abnormal conditions and excessive oil consumption. Check log for accomplishment of following
P/M services as applicable:
Annual
Adjust injectors, crossheads and valves
Check/replace hoses
Check/tighten mounting bolts
Change 8 G-71


 