Custom Search
 
  
 
TM 55-1905-223-24-1
NOTE
Do not reuse the internal preformed packings in the inlet water transfer tubes.
(1)
Remove retaining ring (41, FIGURE 2-12) from side of thermostat housing (44) opposite
water pump.
(2)
Remove section of transfer tube (40) retained by retaining ring (41).
(3)
Remove two preformed packings (39 and 42).
(4)
Remove machine bolts (11) and lockwashers (10) from opposite side of the thermostat
housing (44).
(a)
Use a water tube driver (1, FIGURE 2-13) and a hammer to push the tubes (2) until the tubes clear the
rocker lever housing (3).
(b)
Push the water transfer on the right bank toward the front ofthe engine. Push the water tubes on the
left bank toward the rear of the engine.
FIGURE 2-13. Water Transfer Tube Positioning for Removal