Custom Search
 
  
 
TM 55-1905-223-24-11
REMOVAL
WARNING
Toxic and flammable vapors are generated in the sewage
system.
Provide ventilation from outside source before
removing covers, hoses, drain plugs, and fittings. Avoid open
flames and prolonged breathing of fumes.
WARNING
Make sure the electrical power is OFF to prevent personal
injury.
a. Make sure the external sewage line valves and the backwash water valve are closed.
b. Disconnect the electrical cable from the pump system (paragraph 2-18).
WARNING
Although the system has been drained, a small amount of
effluent may still be contained within the pump. Avoid splashing
in eyes when disconnecting hoses.
c. Disconnect the outlet hose (5, FIGURE 2-20) from the pump at hose clamps (4).
d. Loosen the clamps (1, FIGURE 2-20) and remove the hose (2). Place a shallow pan under the hose
connections while disconnecting to catch any runoff.
e. Remove the mounting screws, nuts, and washers (7, FIGURE 2-20) and remove the pump from the
sanitary unit.
f. Remove the PVC fittings from the pump inlet and outlet (3, 6, FIGURE 2-20).
NOTE
Flush the pump with water and disinfectant before disposal or
further handling.
g. Remove the pump from the motor as follows: (Refer to FIGURE 2-19).
2-74


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business