TM 55-1905-223-24-16
(3) Disconnect failsafe brake pressure line connector (4) from hydraulic motor assembly (5).
b. Remove Hydraulic Motor Assembly. (FIGURE 2-7)
(1) Remove four mounting bolts (5) and four washers (6) from motor flange (4), failsafe brake (9), and mounting
flange (11) on gear reducer coupler (1).
(2) Separate motor (7) from brake (9) by sliding motor shaft (3) out of brake housing. Use suitable soft-face
hammer if necessary.
(3) Remove motor and flange gaskets (2).
REPLACEMENT
a. Install Hydraulic Motor Assembly. (FIGURE 2-7)
NOTE
Apply Permatex sealant to flange gasket prior to installation.
(1) Install flange gasket (2) on motor flange (4).
(2) Position motor (7) and flange gasket (2) into brake housing with boltholes aligned. Use rocking motion to
engage motor shaft (3) with brake coupler.
(3) Install four washers (6) and four mounting bolts (5) and secure motor/ brake assembly to gear reducer
coupler flange (11).
NOTE
Shafts must slide freely together. Do not use bolts to force units together.
(4) Tighten bolts sequentially and torque to 75-85 ft-lb.
2-31


 


Privacy Statement - Copyright Information. - Contact Us