Table 2-2.
Malfunction
Test or Inspection
Corrective Action
STEP 2.  Spark gaps wrong.
Check and reset (.008) (PMCS Table 2-1).
26. Auxiliary power (outage).
STEP 1.  Check for component overload.
Reduce load to 10 amperes.
27. Heating surface not hot.
STEP 1.  Check for tripped circuit breaker.
Reset circuit breaker at galley power panel.
STEP 2.  Make sure all connections are secure.
Tighten connections.
28. Oven not heating.
STEP 1.  Check for tripped circuit breaker.
Reset circuit breaker at galley power panel.
STEP 2.  Hake sure all connections are secure.
Tighten connections.
STEP 3.  Check for defective heating element.
Replace heating element, para. 2-54.
29. Mixer will not start.
STEP 1.  Check for tripped circuit breaker.
Reset circuit breaker at galley power panel.
Push reset button.
STEP 2.
Make sure all connections are secure.
STEP 3.
30. Motor runs but will not change speeds.
STEP 1.  Check for loose speed change lever.
Remove handle, install key, replace handle and snap lock ring.