Custom Search
 
  
 
TM 55-1905-223-24-18-1
Troubleshooting - CONT
Table 2-2.
Malfunction
Test or Inspection
Corrective Action
CENTRIFUGAL PUMP UNIT (AUXILIARY SEAWATER COOLING) - CONT
STEP 5.  Check for damaged pump/motor.
Replace pump/motor, para. 2-99.
ROTARY PUMP UNIT (FUEL OIL TRANSFER)
(PRELUBRICATING OIL TRANSFER)
AND (DIRTY LUBRICATING OIL)
64. Low discharge pressure.
STEP 1.  Check for liquid vortexing (cavitation) in casing.
Release trapped air from pump casing.
STEP 2.  Check for air or gas in liquid.
Identify source and correct problem.
STEP 3.  Check for partially closed pump suction valve.
Ensure pump suction valve fully open.
STEP 4.  Check for partially closed discharge pressure gauge cutoff valve.
Ensure discharge pressure gauge cutoff valve fully open.
STEP 5.  Check for partially clogged pressure line or defective pressure gauge.
Clean pressure line.  Replace pressure gauge.
STEP 6.  Check for air leak(s) in suction piping.
Tighten loose connection(s) in suction piping.
STEP 7.  Check pump/motor for wrong direction of rotation.
Wire motor per instructions given on motor nameplate/decal.
STEP 8.  Check for defective pump.
Replace pump, para. 2-101.
65. Pump motor not running.
STEP 1.
Check for open pump motor circuit breaker.
Reset circuit breaker for No. 1 fuel oil transfer pump at AUX MCHRY MCC
a.
and START/STOP pushbutton and an emergency STOP switch at the pump.
Reset circuit breaker for No. 2 fuel oil transfer pump at emergency
b.
switchboard 240 V distribution and START/STOP pushbutton controller and
an emergency stop pushbutton.
C.
Reset circuit breaker for (prelubricating oil transfer) pump at AUX
MCHRY MCC and START/STOP pushbutton controller adjacent to pump.
2-128


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business