Custom Search
 
  
 
TM 55-1905-223-24-18-1
Table 2-2.
Troubleshooting
Malfunction
Test or Inspection
Corrective Action
GYRO INTERFACE ASSEMBLY - CONT
b.
Stopping motor type inputs - reverse connections 1 and 2 on the
terminal strip labeled Gyro Transmission Unit in the gyro interface
unit.
68. System does not operate.
STEP 1.  Check for incorrect or disconnected wiring.
Recheck wiring diagram for proper connections.
STEP 2.  Check for mechanical binding of gears in gyro interface.
Disconnect stepper or synchro input to gyro interface. Rotate brass
knurled knob so that course dial rotates freely through 360' rotation.
Adjust backlash if necessary.
STEP 3.
Check to see if the gyro transmission unit output switch is in the
correct position.
Turn gyro transmission switch to ON position.
2-130


 