Custom Search
 
  
 
TM 55-1905-223-24-18-1
Troubleshooting - CONT
Table 2-2.
Malfunction
Test or Inspection
Corrective Action
COMPRESSED AIR PIPING SYSTEM - CONT
STEP 4.
Check for leaking moisture separator.
Isolator separator.
b.
Repair or replace as necessary.
STEP 5.
Check for defective pressure relief valves.
I n s p e c t relief valves.
b.
Locate and isolate faulty valve.
Repair or replace valve.
c.
STEP 6.
Check for defective air dryer.
Inspect air dryer.
b.
Isolate, repair or replace dryer. Refer to air compressor
troubleshooting (TM 55-1905-223-24-8).
Check for defective compressor.
STEP 7.
Pressure loss in piping main.  Piping main pressure gauges indicate low
225.
pressure (below 220 psig) and constant need to run compressors.
Check for piping failure in piping main/piping branches or serviced
STEP 1.
equipment.
Inspect piping.
Locate and isolate faulty piping.
b.
Repair or replace as necessary (para 2-342).
c.
Check for relief valve failure in piping main/piping branches or
STEP 2.
serviced equipment.
Inspect relief valve.
Locate and isolate faulty relief valve.
b.
Repair or replace as necessary (para 2-342).
c.
Check
for hose/connection failure to serviced equipment.
STEP 3.
Inspect
hose connections.
Locate
and isolate faulty hose/connections and replace as necessary
b.
Check for leaking air serviced equipment.
STEP 4.
Inspect equipment.
Locate and isolate faulty equipments.
b.
Repair or replace as necessary.
c.
2-171


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business