Custom Search
 
  
 
TM 55-1905-223-24-M-1
c.
Remove Coalescer Element.
CAUTION
Wait until water has drained below the level
of the cover before opening the cover.
(1) Loosen and remove clamp (9, FIGURE 2-20) securing cover (8) to third stage
vessel.
(2) Remove cover (8).
(3) Loosen and remove wing nut (3) from threaded filter support (6).
(4) Remove packing retainer (2), preformed packing (4) and hold down plate
(1) .
(5) Remove coalescer element (5).
REPAIR
Repair at the unit level consists of cleaning the inside of the 3rd stage vessel
and replacing the coalescer element (5), preformed packing (4), packing retainer
(2), and self-locking wing nut (3).
ASSEMBLY
CAUTION
It is important that coalescer element be
handled properly.  DO NOT touch or handle
the sock area (side covering) of the
coalescer.  Contamination of this surface by
any oils, including skin oils, may prevent
the coalescer element from functioning
properly and cause foaming in the effluent.
Handle coalescer element only by the end
cap.  When installing element, insert hand
through opening on the end cap.
a.
Place coalescer element (5) over the threaded support (6) so that it is
centered over the element positioning guide (7).
Replace and center hold down plate (1) over end cap of the coalescer element,
b.
c.
Replace preformed packing (4), packing retainer (2) and self-locking wing nut
(3).
d.
Tighten self-locking wing nut (3) as tightly as possible by hand.
There are
no torque requirements.