Custom Search
 
  
 
TM 55-1905-223-24-18-1
2-129.
Repair Engine Room Multi-Remote Module.
This task covers:
a. Removal, b. Repair, c. Replacement.
INITIAL SETUP
Tools
Equipment Condition
T o o l kit, electrician's,
Electrical power to monitoring and
alarm system secured and tagged
"Out of Service - Do Not Operate."
Materials/Parts
(TM 55-1905-223-10)
D i g i t a l display indicator (2)
P/N 61-4250-000
Liquid level switch P/N 61-1700-002
Liquid level switch P/N 61-1700-003
Warning tag, Item 1, Appendix C
REMOVAL
Disconnect electrical cables K-C056 (1) and K-C057 (4) from liquid level
a.
switches (2, 3) and cables K-C060 (5) and K-C061 (7) from digital indicators
(6, 8).
b.
Remove attaching hardware and liquid level switches (2,3).
c.
Remove attaching hardware and digital indicators (6,8).
REPAIR
Repair at this level of maintenance is by replacement of liquid level switches
(2, 3) and digital indicators (6, 8).
REPLACEMENT
Secure with attaching hardware.
a.
I n s t a l l digital indicators (6, 8).
Secure with attaching hardware.
b.
I n s t a l l liquid level switches (2, 3).
c.
Connect electrical cables K-CO56 (1), K-CO57 (4), K-CO60 (5) and K-CO61 (7).
Remove tag and turn on electrical power.
d.
Change 1


 