Custom Search
 
  
 
TM 55-1905-223-24-18-1
Repair Port Engine Remote Module.
2-130.
This task covers:
a. Removal, b. Repair, c. Replacement.
INITIAL SETUP
Equipment Condition
Tools
Electrical power to controls system
T o o l kit, electrician's,
secured and tagged "Out of Service
Do Not Operate".
(TM 55-1905-223-10)
Materials/Parts
Solid state switch P/N 91-2003-0000
Solid state switch P/N 86435
Pressure switch P/N 1836-A2J
Pressure switch P/N PlS-3030
Liquid level switch P/N 61-17001-001
Liquid level switch (2)
P/N 61-2050-000
Warning tags, Item 1, Appendix C
REMOVAL
NOTE
Prior to performing maintenance at the unit level, intermediate
direct support maintenance must first remove the electrical
power cables.
a.
Loosen captive screws (1) and open cover (2) on enclosure (3, Sheet 1).
b.
Tag and disconnect electrical leads and remove solid state switch (4).
Remove liquid level switch (5, Sheet 2).
c.
Remove solid state switch (6).
d.
Remove liquid level switch (7).
e.
Remove pressure switch (8).
f.
Remove liquid level switch (9).
g.
Remove pressure switch (10).
h.
Change 1
2-509


 


Privacy Statement - Copyright Information. - Contact Us