Custom Search
 
  
 
TM 55-1905-223-24-18-1
Repair Motor Controller Multi-Remote Module.
2-141.
a. Disassembly, b. Repair, c. Assembly.
This task covers:
INITIAL SETUP
Tools
Equipment Condition
Secure electrical power to motor
T o o l kit, electrician's,
controller multi-remote module
and tag "Out of Service - Do Not
Operate" at ship service switchboard.
Materials/Parts
Solid state switch P/N 91-2003-000
Solid state switch P/N 91-2000-000
Warning tag, Item 1, Appendix C
NOTE
Prior to performing maintenance at the unit level,
intermediate direct support maintenance must first remove the
electrical power cables.
Loosen captive screws (1) and open cover (2).
a.
Remove solid state switches (3, 4).
b.
Repair at this level of maintenance is by replacement of solid state switches (3,
4).
I n s t a l l solid state switches (3, 4).
a.
Close cover (2) and tighten captive screws (1).
b.
Restore power.
c.
Change 1
2-536


 


Privacy Statement - Copyright Information. - Contact Us