Custom Search
 
  
 
TM 55-1905-223-24-18-1
(e) Remove mounting screws (6). Remove box (5).
(2) Remove receptacle P/N 2634A (FIGURE 2-154).
(a) Remove screws (1).
(b) Remove cover.
(c) Disconnect wiring from receptacles.
(d) Remove mounting screws (4). Remove body (3).
(3) Remove receptacles P/N 2702A and 2702AF (FIGURE 2-155).
(a) Remove screws (2) and cover (1).
(b) Remove screws (3).
Pull out receptacle (4).
(c) Remove wiring from receptacle (4). Remove receptacle (4).
c. Remove Incandescent Lamp (FIGURE 2-156)
WARNING
Hot lamps can cause burns. Wear gloves when
removing hot lamps.
(1) Unscrew and remove cage (4), if attached.
(2) Unscrew and remove globe (3).
(3) Remove bulb (2).
d. Remove Fluorescent Lamps.
(1) Remove fluorescent lamps from ceiling fixtures (FIGURE 2-157).
(a) Remove knurled screws (5) and lens frame (1).
(b) Unclip and swing down or remove lens (3).
(c) Use two hands to grasp both ends of fluorescent lamp (2).
(d) Rotate lamp (2) until loose.
(e) Remove lamp (2).
(2) Remove exit light lamp (FIGURE 2-158).
(a) Remove knurled screws (1).
(b) Remove cover (3).
(c) Use two hands to grasp both ends of fluorescent lamp (2).
2-631


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business