TM 55-1905-223-24-18-1
Replace/Repair Power Distribution Panel P106.
2-183.
This task covers:
a. Removal, b. Repair, c. Replacement
INITIAL SETUP
Tools
Equipment Condition
Tool kit, electrician's,
Main switchboard GALLEY 120V PANEL
P106 BOAT circuit breaker OFF and
tagged "Out of Service - Do Not
Materials/Parts
Operate."  TM 55-1905-223-10.
Circuit breaker P/N Q215H
Circuit breaker P/N Q220H
Circuit breaker P/N Q225H
Warning tag, Item 1, Appendix C
WARNING
Death, serious injury, or equipment damage
can result from contact with live electrical
c i r c u i t s .  'Before beginning work on this, or
any other electrical equipment, turn power
and control voltage circuit breakers OFF a n d
tag "Out of Service - Do Not Operate."
Refer to the procedures in paragraph 2-178 to replace and repair the power
d i s t r i b u t i o n panel, door assembly, plug in breaker unit and main interior lug.