Custom Search
 
  
 
TM 55-1905-223-24-18-1
Remove cotter pins (5) from cylindrical pins (3).
c.
Remove cylindrical pins (3) from hinge blades (2).
d.
Remove flat washers (4) then remove door (1).
e.
DISASSEMBLY
NOTE
Disassembly/assembly procedures for both
left and right hand doors are the same.
Remove hex nuts (6, FIGURE 2-169) and handles (7) from door (1).
a.
Remove bronze bushing (5) and preformed packing (4) from door.
b.
Remove dog door closer (9) from door.
c.
NOTE
Refer to TM 55-1900-204-24 for detailed
cutting and welding procedures,
Remove pipe sleeve (8) from door.
d.
Remove gasket retainer (10) and gasket (11) from door.
e.
Clean gasket channel thoroughly.
f.
NOTE
After removing the old gasket, the entire
gasket channel should be thoroughly cleaned.
Remove stops (2) and flanged plate (3) from door.
g.
Remove light assembly (12) from door.
h.
REPAIR
Repair at this level of maintenance is by replacement of:  gasket (11), preformed
packing (4), oilite bronze bushings (5), fixed light assembly (12) and defective
structural parts of the door.
ASSEMBLY
Install flanged plate (3) and stops (2) on door (1).
a.
Measure the required length around the door for the gasket.
b.
Add one additional inch and cut gasket.
c.
2-676


 